[ Insulation Basics ] [ R-Value Drift ] [ Thermal Breaks ] [ Whole Wall R-Value ] [ Moisture Barriers ] [ Air Barriers ] [ Vapor Retarders ] [ Ice Dams ] [ Ventilation Basics ] [ Vented vs. Unvented Roofs ] [ Noise Reducing Barriers ] [ Theory vs. Practice ] [ Sustainability ] Combined cavity and framing wall values
Framing member & spacing
|
Insulation types
|
Nominal Cavity R-value
|
Wood framed system
|
Steel Framed System
|
2 x 4 16" o.c.
|
Fiberglass batt
|
11
|
9.16
|
5.5
|
13
|
10.36
|
5.98
|
15
|
11.47
|
6.45
|
FOAM-TECH Closed cell
foam
|
24.5
|
15.68
|
12.25
|
FOAM-TECH Open cell foam
|
12.6
|
10.13
|
5.42
|
|
|
|
|
|
2 x 4 24" o.c.
|
Fiberglass batt
|
11
|
9.7
|
6.6
|
13
|
11.11
|
7.15
|
15
|
12.44
|
7.8
|
FOAM-TECH Closed cell
foam
|
24.5
|
17.82
|
14.7
|
FOAM-TECH Open cell foam
|
12.6
|
10.84
|
6.55
|
|
|
|
|
|
2 x 6 16" o.c.
|
Fiberglass batt
|
19
|
15.45
|
7.03
|
21
|
16.61
|
7.35
|
FOAM-TECH Closed cell
|
38.5
|
24.64
|
14.25
|
FOAM-TECH Open cell
|
19.8
|
15.92
|
7.33
|
|
|
|
|
|
2 x 6 24" o.c.
|
Fiberglass batt
|
19
|
16.47
|
8.55
|
21
|
17.86
|
9.03
|
FOAM-TECH Closed cell
|
38.5
|
28
|
17.33
|
FOAM-TECH Open cell
|
19.8
|
15.92
|
8.91
|
|