Combined cavity and framing wall values

Framing member & spacing

Insulation types

Nominal Cavity R-value

Wood framed system

Steel Framed System

2 x 4 16" o.c.

Fiberglass batt

11

9.16

5.5

13

10.36

5.98

15

11.47

6.45

FOAM-TECH Closed cell foam

24.5

15.68

12.25

FOAM-TECH Open cell foam

12.6

10.13

5.42

 

 

 

 

 

2 x 4 24" o.c.

Fiberglass batt

11

9.7

6.6

13

11.11

7.15

15

12.44

7.8

FOAM-TECH Closed cell foam

24.5

17.82

14.7

FOAM-TECH Open cell foam

12.6

10.84

6.55

 

 

 

 

 

2 x 6 16" o.c.

Fiberglass batt

19

15.45

7.03

21

16.61

7.35

FOAM-TECH Closed cell

38.5

24.64

14.25

FOAM-TECH Open cell

19.8

15.92

7.33

 

 

 

 

 

2 x 6 24" o.c.

Fiberglass batt

19

16.47

8.55

21

17.86

9.03

FOAM-TECH Closed cell

38.5

28

17.33

FOAM-TECH Open cell

19.8

15.92

8.91